Sign In | Join Free | My polstate.com |
|
Brand Name : GETINGE
Model Number : 6640044
MOQ : 1
Payment Terms : Western Union,T/T
Delivery Time : 3-5 working days
BRAND : GETINGE
Product Situation : Used In Good Condition
WARRENTY : 90 Days
Product Information : Good In Function
Parameters : ECG,TEMP,RESP,NIBP,SPO2 and the like
Shape : standard
Applicable Equipment : PHiliph MP70
Storage Humidity : 10 to 95%, noncondensing
Condition : Work in Good
Delivery : 3-5 Working Days
GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts
GETINGE O2 cell serve ventilators Oxygen Battery 6640044 is a Original Medical Device Battery Specifications,Medical Device Battery Specifications.Energy supply unit for medical equipment with replaceability and energy storage function. Ensures continuous operation of medical devices during clinical procedures.
Attribute | Value |
Brand | GETINGE |
Product Name | Oxygen Battery |
Model | 6640044 |
Condition | Original |
Material | Plastic |
Color | white |
MOQ | One Piece |
Payment Terms | T/T(wire transfer), Western Union, Paypal |
Warranty | 90 days |
This OEM GETINGE Oxygen Battery (Model 6640044) provides fail-safe power redundancy for SERVO-i/SERVO-u ventilator series, ensuring uninterrupted respiratory support during critical care scenarios. Manufactured to medical-grade standards (ISO 13485:2016 certified), this white polycarbonate-encased power unit delivers peak performance with integrated safety protocols.
Attribute | Specification |
Chemistry | Lithium-ion (LiFePO₄) |
Nominal Voltage | 14.8V DC |
Capacity | 6600mAh (97.68Wh) |
Cycle Life | ≥500 cycles (80% capacity retention) |
Operating Temp | 5°C to 40°C (41°F to 104°F) |
Shelf Life | 12 months from 2026-05-15 production date |
Core Functionality:
Automatic Failover: Seamless AC-to-battery transition in <15ms during power interruptions
Real-time Monitoring: 4-stage LED capacity indicator (25% per bar) with low-battery
Multi-Layer Protection:
Overcharge/discharge cutoff
Short-circuit lockdown
Temperature-triggered current limitation
Performance Advantages vs. Generics:
Parameter | OEM 6640044 | Generic Equivalent |
Ventilator Runtime | 4.5–5.5 hours* | 2–3 hours |
Recharge Cycles | 500+ | ≤300 |
Safety Certifications | IEC 62133-2:2017 | Non-compliant |
*At continuous 6L/min O₂ flow with 15 BPM setting |
|
|
Installation Procedure:
Safety Check: Verify hands are dry and grounded
Alignment: Position battery label-side up, aligning grooves with ventilator's docking rails
Engagement: Slide firmly until audible click confirms magnetic latching
Verification: Confirm 4-bar status on ventilator control panel
Removal Protocol:
Depress recessed release button (tactile feedback confirms activation)
Slide unit outward using thumb ridges - never pull wiring harness
Immediately place in static-shielding bag during transport
Optimal Charging Practice:
Partial Cycling: Maintain 40-60% charge during storage (extends lifespan 200%)
Reconditioning: Full discharge/charge every 6 months to calibrate fuel gauge
Storage Temp: 15°C–25°C (59°F–77°F) in 30-50% humidity
Fire Prevention Protocol:
Maintain 5-meter (16.4 ft) radius clearance from:
Oxygen tents
Alcohol-based sanitizer stations
Electrocautery equipment
Mandatory installation of Li-ion fire containment bag (e.g., Li-ion Fire Bag®) in storage areas
Operational Restrictions:
Scenario | Required Action |
Nocturnal ventilation | Dual batteries + AC power mandatory |
Transport monitoring | Max 2 units per containment case |
Post-impact damage | Immediate quarantine & testing |
This unit passes GETINGE's 72-hour stress protocol:
Deep Discharge Test: 0% to shutdown voltage (10.5V) with 2A load
Rapid Charge Verification: 0-80% in 55 mins (certified charger)
Thermal Cycling: -20°C to 50°C ambient temperature exposure
Vibration Resistance: 5G RMS random vibration per MIL-STD-810G
Package Includes:
GETINGE 6640044 Battery (2026-05-15 production batch)
ESD-safe transport container with humidity indicator
Certificate of Conformance (Trace# [REDACTED])
EU MDR 2017/745 Annex VIII
FDA 21 CFR Part 870.2700
UN38.3 Transport Certification
RoHS 3 (2015/863/EU) Test Report
Clinical Impact Statement
"During our hospital's generator failure, four SERVO-u ventilators with these batteries maintained ECMO support for 217 minutes - exceeding OEM runtime claims. Their precise fuel gauging prevented unexpected shutdowns."
– Biomedical Engineering Director, University Hospital
Actionable Next Steps
Contact our life-support specialists for:
① Batch-specific test reports
② Ventilator compatibility verification
③ Hospital battery rotation program templates
![]() |
GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts Images |