Sign In | Join Free | My polstate.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Defibrillator Machine Parts >

Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator

Brand Name : FUKUDA

Model Number : 10N-1700SCC

MOQ : One Piece

Payment Terms : T/T, Western Union,Paypal

Delivery Time : 3-5 working days

Packaging Details : Canton

Product Name : Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator

Brand : FUKUDA

Part No : 10N-1700SCC

MOQ : One piece

Warranty : 90 days

Condition : Work in Good

Compatible with : FUKUDA FC-1760 Defibrillator

Battery charge time : Approx. 150 minutes

Battery operation time : 1 hour when operated for monitoring purpose only

Power requirements : 115V AC 10% or 230V AC 10%, 50/60Hz ;170VA max., or 12V DC rechargeable battery

Capacity : 12V 1700mAh

Packaging : Carton

Contact Now

FUKUDA FC-1760 Defibrillator Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh

About FUKUDA FC-1760 Defibrillator Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh

FUKUDA FC-1760 Defibrillator Rechargeable Battery Pack 10N-1700SCC allows for 30 charge and discharge cycles when fully charged. The battery also enables use of the device as a simplified monitor for up to one hour.

Specification of FUKUDA FC-1760 Defibrillator Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh

Product Name

FUKUDA FC-1760 Defibrillator Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh

Part No 10N-1700SCC
Compatible with FUKUDA FC-1760 Defibrillator
Battery charge time Approx. 150 minutes
Battery operation time 1 hour when operated for monitoring purpose only
Power requirements 115V AC 10% or 230V AC 10%, 50/60Hz ;170VA max., or 12V DC rechargeable battery
Capacity

12V 1700mAh

How to charge the battery

1. Use a genuine charger.

Using an original charger is the first requirement to ensure safe charging of the battery. Genuine chargers are rigorously tested and certified to meet the battery pack's charging requirements. and can provide stable and appropriate current and voltage.

2. Avoid over-charging and over-discharging.

Overcharging and overdischarging will have a negative effect on the life of the battery. Therefore, you should try to avoid filling or discharging the battery to very low levels during the charging process. Generally, charging the battery pack to about 80% or discharging to about 20% is a more suitable range.

3. Avoid charging in a high temperature environment.

High temperatures will damage batteries as they age. Therefore, you should choose a cool environment when charging to avoid exposing the battery pack to high temperatures. If the battery pack overheats while charging Stop charging and check in.

4. Charge and discharge regularly.

Even if the battery pack is not in use But it must be charged and discharged frequently. This can help the battery last and prevent it from deteriorating over time without use.

5. Avoid charging too quickly.

Charging too quickly can cause the battery pack to overheat and be damaged. Therefore, choose the appropriate charge level when charging and avoid using a charger that is too fast.

Cautions

1. Avoid overcharging and overshipping.

In addition to avoiding overcharging and over-discharging while charging, You should try to avoid charging or discharging the battery to very low levels during daily use. This will prolong the life of the battery pack.

2. Avoid charging frequently.

Frequent charging puts pressure on the battery pack. which affects the service life Therefore, you should avoid charging it frequently. unless necessary

3. Avoid leaving it unused for a long time.

A battery pack that has not been used for a long time may self-discharge. This causes the battery to become too low or unable to charge properly. Therefore, batteries that have not been used for a long time should be charged and discharged frequently.

4. Avoid using inappropriate chargers.

Using an improper charger may cause the battery to overcharge or over-discharge. This can damage the battery. So try using the original charger or a certified charger.

5. Avoid excessive vibration and collision.

Excessive vibration and collision will cause damage to the internal structure of the battery. This affects the performance and life of the battery. Therefore, excessive vibration and collision should be avoided during use.

Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator

Thank you so much for your attention .If you're interested in Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator ,feel free to contact us .Thank you .


Product Tags:

1700mAh Rechargeable Battery Pack

      

FC-1760 Rechargeable Battery Pack

      

12V 1700mAh Rechargeable Battery Pack

      
Wholesale Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator from china suppliers

Rechargeable Battery Pack 10N-1700SCC 12V 1700mAh For FUKUDA FC-1760 Defibrillator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)