Brand Name : Dräger
Model Number : 8411130
MOQ : 1
Payment Terms : T/T, Western Union,PayPal
Delivery Time : 3-5 working days
Product name : Dräger Spirolog Flow Sensor
Order number : 8411130
Warranty : 90days
Cuvette : Polycarbonate (PC)
Sensor insert : Acrylonitrile butadiene styrene (ABS) with 13 µm platinum wire
Temperature : –20 to 60 °C (–4 to 140 °F)
AtmosPHilipheric pressure : 500 to 1060 hPa (7.25 to 15.37 psi)
Relative humidity : 10 to 95 % (no condensation)
Measuring principle : Hot-wire anemometry
Post-sales service : In the warranty period and non-human damage can go to the sale free of charge for new
Goodness : Original
Minimum purchasing quantity : 1 unit
Delivery Terms : Express
Drager Neonatal Straight Flow Sensor ISO15 8411130 for Straight flow sensor for Babylog® 8000/Evita® 4/ Evita 2 dura®/Evita® NeoFlow.
►Brief Introduction
The measurement principle used in flow measurement is the hot wire velocimetry method.Hot wire velocimetry is a thermal measurement method in which the measuring line of the flow meter remains at a constant high temperature during the measurement process. The higher the flow rate, the more energy is required to maintain a constant high temperature. The flow rate can then be calculated from the energy consumed. To ensure proper functionality, check for visible damage, dirt and particles before inserting the flow meter. Repeat this check regularly. If the flow meter is damaged, dirty, or contains particles, replace it. If the measurement line of the flow meter continues to glow during operation, it is a sign of dirt. Reprocess or replace the flow meter immediately.
Work for Draeger Inc.
► Safety-related information
Flow sensors
Flammable substances
The flow sensor may ignite medications or other substances based on easily flammable substances. The patient may be put at risk.
Residual vapors of highly flammable disinfectants
Residual vapors of highly flammable disinfectants (e.g., alcohols) and deposits that were not removed during reprocessing may ignite when the flow sensor is in use.
The patient may be put at risk.
► Steps
1. Pull out the flow meter (6) from the Y-piece (5).
2. Unplug the flow meter cable plug (7) from the flow meter (6).
3. While gently pressing the knobs (8) on both sides, pull the flow meter insert (9) out of the flow meter housing (10).
► Specification
Item | NEONATAL FLOW SENSOR ISO15 |
OEM | Draeger Inc. |
OEM # | 8411130 |
Returnable | No |
Standards | ISO 15 |
If you have any questions about Drager Neonatal Straight Flow Sensor ISO15 8411130 for Straight flow sensor for Babylog® 8000/Evita® 4/ Evita 2 dura®/Evita® NeoFlow., please feel free to contact us at any time, we are glad to answer them. Looking forward to receiving your early inquiry. Thanks for Your Cooperation.
![]() |